• Skip to secondary menu
  • Skip to main content
  • Skip to primary sidebar
  • About Us
  • Contact Us
  • Disclaimer
  • Privacy Policy
  • Write for Us
  • Free HVAC Quotes

Daily Heating and Air Conditioning

  • Amana
  • American Standard
  • Bryant
  • Carrier
  • Goodman
  • Lennox
  • Rheem
  • Trane

You are here: Home / Trane Heat Pumps / Trane XR13 Repair and Troubleshooting Guide
Get FREE Quotes

Trane XR13 Repair and Troubleshooting Guide

Trane XR13 Heat Pump Troubleshooting Guide

If you are experiencing an issue with your Trane XR13 heat pump and air conditioning system, this article will guide you how to troubleshooting the problems.

As an industrial machine, you’ll encounter some issues in an old Trane xr13 heat pump, as that air conditioner unit will break down as they age. Chances are, you won’t be an expert in repairing these devices, but you can take some practical steps to solve problems and help get your systems operational again in a timely manner.

Check the Trane xr13 manual book to prepare anything you will need later on the troubleshooting process.

This Trane XR13 troubleshooting guide will help you determine what might be wrong with your Heat Pump. And you can diagnose and repair the most common problems before you pay a contractor’s service.

Common Trane XR13 troubleshooting and possible solutions.

Trane XR13 Blowing Cold Air

Your outdoor cooling coil may be clogged or blocked
Debris can easily stick to the inlet side of the cooling coil in your unit. Be sure to clear away any tall grass, sticks, or leaves that may be surrounding your outdoor unit.

Your indoor air handler coil could be blocked
Ordinary house dust and debris like soot or pollen can block indoor air handler coils. For your indoor air handler, try to wipe away any buildup of dust on the coil and change the air filter often.

Your filters may be clogged or dirty
Clean or replace the trane xr13 filters. Consult your local Trane Comfort Specialistâ„¢ if you are unsure where the filters are located.

Your thermostat controls may be set incorrectly
Try turning the thermostat off and then on again. Reset to the desired temperature and see if that helps.

Trane XR13 No Air Blowing

The trane xr13 air handler might not be working because of a blown fuse or open circuit breaker. Reset the circuit breaker or replace the burned-out fuse. You should also check return grills for blockages that could keep air from circulating freely in the system.

Trane XR13 Constantly Running

Your thermostat could be set too high. Reset your thermostat by turning it on and off, then adjust the temperature to a comfortable level.

Trane XR13 Drain Pan Overflowing

The drain pan below your trane xr13 interior AC unit collects condensation. An electric pump is supposed to move this condensation to a nearby drainage pipe. The pump might have come unplugged or there may be kinks or blocks in the drainage line. Contact your local Trane Comfort Specialistâ„¢ if you need help.

Trane XR13 Making Odd Noises

If you hear rattling sounds coming from your trane xr13 heat pump, it could simply be loose hardware or an out-of-place register.

Before doing trane xr13 troubleshoot, it is important to ensure that the routine maintenance has been performed on the system. If the routine maintenance has been done, it is time to find the problem. Maintenance, repairs and replacement of an Trane xr13 AC/heat pump bring the best value when they are done properly.

HVAC Technicians

Related Posts

  • Trane XR13 Compressor Guide – Problems & Repair Tips
  • Trane Heat Pumps Prices and Buying Guide
  • How to Decode the Trane Model Number
  • Trane XR13 Manual – PDF
  • Trane XR14 Heat Pump Specifications & Reviews
  • Diagnose and Repair Capacitor in Trane XR13

Get Free Quotes
CALL 855-928-3617 to REQUEST APPOINTMENT

The Daily Thrive Author

Have been in the heating and air conditioning (HVAC) industry for over 20 years. He is person that will grow and thrive to learn more about the HVAC industry throughout his career. Mas Broto is also a blogger, who's dedicated to bringing you the best knowledge to get ahead in the game of life.

Newsletter Subscription

Get the latest tips, hacks, and posts delivered to your inbox for free!


Primary Sidebar

Looking for Something?

Connect with us online

  • Facebook
  • Instagram
  • Pinterest
  • Twitter
  • YouTube

HVAC System Costs 2021

Central Air Conditioner$3,500 – $7,500
Ductless Split AC$3,000 – $5,000
Heat Pump$5,000 – $6,500
Electric Furnace$1,500 – $2,500
Gas Furnace$4,000 – $5,000
Oil Furnaces$5,500 – $6,500

The average cost to replace an HVAC system is $3,000 to $9,500. Installation of a new HVAC system with ductwork costs between $5,000 and $12,500 in total.

We can help find the right HVAC system for your home!

Get FREE Estimes

New Articles

  • Coleman Air Conditioner Price – Warranty – Reviews
  • How to Read Coleman Furnace Model Number
  • Amana Air Conditioner Reset Button Location
  • Amana ASX16 Air Conditioner Price and Reviews
  • Carrier Air Conditioners Manual – Owner’s Guide
  • Lennox Furnace Troubleshooting Guide
  • How to Read Lennox Model Number

Categories

Daily Heating and Air Conditioning Copyright © 2021